[Solved] The radical distribution is simple and economical, but the r (2024)

When the distributor is connected to a substation on one end only with the help of feeder, then the system is called a radial distribution system.

The feeders, distributors and service mains are radiating away from the substation hence name given as radial system.

There are combinations of one distributor and one feeder, connecting that distributor to the substation.

[Solved] The radical distribution is simple and economical, but the r (1)

In the above diagram, one end of distributors is connected to the substation with the help of feeders and the other end will be connected to the service mains.

In this distribution system, electricity is distributed from a single point in a radial distribution system. The fluctuation in the supply is moreat the consumer’s terminal.

Therefore,Both Statement I and Statement II are individually true but Statement II is not the correct explanation of Statement I.

Note:

Radial Distribution System:

This system is used only when the substation is located at the center of the consumers. In this system, different feeders radiate from a substation and feed the distributors at one end. Thus, the main characteristic of a radial distribution system is that the power flow is in only one direction. It is the simplest system and has the lowest initial cost but it is not highly reliable.

Major drawbacks of a radial distribution system are,

  • A fault in the feeder will result in supply failure to associated consumers as there won't be any alternative feeder to feed distributors.
  • Voltage is affected much at far awayload from the substation.


Ring main system:

In this system, each distribution transformer is fed with two feeders but in different paths. The feeders in this system form a loop which starts from the substation bus-bars run through the load area feeding distribution transformers and returns to the substation bus-bars.

Ring main distribution system is the most preferred due to its following advantages:

  • There are fewer voltage fluctuations at the consumer's terminal.
  • The system is very reliable as each distribution transformer is fed with two feeders. That means, in the event of a fault in any section of the feeder, the continuity of the supply is ensured from the alternative path.
  • Voltage is affected lessat far away load from the substation.


Interconnected distribution system:

When a ring main feeder is energized by two or more substations, it is called as an interconnected distribution system. This system ensures reliability in an event of transmission failure. Also, any area fed from one generating station during peak load hours can be fed from the other generating station or substation for meeting power requirements from the increased load.

[Solved] The radical distribution is simple and economical, but the r (2024)
Top Articles
Latest Posts
Article information

Author: Catherine Tremblay

Last Updated:

Views: 5572

Rating: 4.7 / 5 (67 voted)

Reviews: 82% of readers found this page helpful

Author information

Name: Catherine Tremblay

Birthday: 1999-09-23

Address: Suite 461 73643 Sherril Loaf, Dickinsonland, AZ 47941-2379

Phone: +2678139151039

Job: International Administration Supervisor

Hobby: Dowsing, Snowboarding, Rowing, Beekeeping, Calligraphy, Shooting, Air sports

Introduction: My name is Catherine Tremblay, I am a precious, perfect, tasty, enthusiastic, inexpensive, vast, kind person who loves writing and wants to share my knowledge and understanding with you.